Scope
Steps to install the Central Link v12 used for updating Teachers2Parents from centrally hosted SIMS.
Instructions – Installing the Central Link v12
- Go to Admin > Options.
- In General, confirm that the School Database System (MIS) is set to SIMS.
- If so, go to Step 3.
- If not, select that option from the drop-down and click Save. Click OK on the pop-up to return to Home to apply that change. Continue to Step 3.
- Go to Setup SIMS > Citrix Link V2.10.0.
- Click Run when prompted. If it downloads the file instead, open it and then click Run.
- For Publisher cannot be verified, click Run again.
- Note: If you see an error message window that says Couldn’t load library at this stage, read our guide for further information: Teachers2Parents: Couldn’t Load Library Error.
- The T2P-SIMS-Link-Central-V2.12.0 window will open in the bottom right.
- Click Settings.
- In T2P Username and T2P Password, enter your login details for Teachers2Parents > Save.
- In the confirmation window, click OK.
- Close the T2P-SIMS-Link-Central-V2.12.0 window.
Instructions – Importing the Report in SIMS
- In SIMS, go to Reports > Import > Open.
- Click on Hosted SIMS.
- Go to C: Drive (normally labelled as C on office… or c: client v) > T2PSimslink
- Double-click on the A_T2P_Central_V2.12.0.RptDef file. It will appear in the Import window with the name A_T2P_Central_v11 and the status Pending.
- Click Import and the status will change to Imported > Close.
Instructions – Running the Report in SIMS
- In SIMS, go to Reports > Run Report.
- Expand the Focus folder > Student > double-click A_T2P_Central_V11:
- If the window says …report has been created, click OK and minimize SIMS. Continue to the next section.
- If the window says Unable to create file… then follow these steps to resolve:
- Go to Reports > Design Report > Open an Existing Report.
- Expand the Focus folder > Student > double-click A_T2P_Central_V11.
- Click Finish > Back to go to the Define Presentations page.
- In the file name you will have a predefined path of \tsclientcT2PSimslinkt2p_pupil_contacts.xml.
- Select and copy t2p_pupil_contacts.xml from the end of the path.
- Click Browse.
- Go to Hosted SIMS > C: Drive (normally labelled as C on office… or c: client v) > T2PSimslink.
- Paste t2p_pupil_contacts.xml into the file name.
- Click Save > Finish > Save My Report > OK.
- Close all the pages open in SIMS until you are on the first page showing the SIMS logo.
- Return to Step 1 above and retry.
Instructions – Completing the Update
- On your Desktop, double-click the t2p_sims_link-2.12.0 icon.
- This should open a window that says Opening file… to indicate it is updating.
- It will open an Internet Explorer window telling you to Click here to complete your update.
- Once you click it, it will confirm that import has finished and to close the window.
- After the Opening file… window closes, the T2P-SIMS-Link-Central-V2.12.0 window will reappear in the bottom right-hand corner. Close this window.